Key Specification
RG-N18012 Cloud Network Layer 3 Modular Core Switch with 12 Module Slots
Switch fabric module slot | 4 |
---|---|
Supervisor module slot | 2 |
Power module | System power: 6 PoE power: 2 (the power module must adapt to the PoE power frame) |
Data packet buffer | ED card: 5 MB DC card: 16 MB 12CQ-EH: 16 MB |
CPU | Supervisor module: ● M18012-CM II: 1.0 GHz 32-core processor Line card: ● ED/DC: 1.0 GHz quad-core processor Switch fabric module: ● M18012-FE-D I: 1.0 GHz quad-core processor |
Dimensions (W x D x H) | 442 mm x 725 mm x 708.4 mm (17.40 in. x 28.54 in. x 27.89 in.), 16 RU |
Number of VSU members | 2 |
Number of MLD groups | 1,024 |
Number of IPv6 multicast routes | ● ED card: 8,000 (default) ● DC card: 8,000 (default) ● EH card: 2,000 (default) and 4,000 (max.) |
Number of IPv4 multicast routes | ● ED card: 16,000 (default) ● DC card: 16,000 (default) ● EH card: 4,000 (default) and 8,000 (max.) |
ND table size | ED card: 75,000 (default) DC/EH card: 45,000 (default) |
MAC address | Number of global MAC addresses: ● ED card: 128K (default) and 512K (max.) ● DC card: 96K (default) and 288K (max.) ● EH card: 136K (default) and 136K (max.) Number of static MAC addresses: 10,000 |
Operating Temperature | 0°C to 50°C (32°F to 122°F) with the height in the range of –500 m to +5,000 m (–1640.42 ft. to + 16404.20 ft.) |
MTBF | > 200,000 hours |
Rated input voltage | RG-PA1600I: 100 V to 120 V, 200 V to 240 V, 50/60 Hz RG-PA600I: 100 V to 120 V, 200 V to 240 V, 50/60 Hz RG-PD600I: –48 V DC |
Operating noise | 63.5 dB at the temperature of 35°C (95°F) 77.4 dB at the temperature of 50°C (122°F) |
Operating Humidity | 10% to 90% RH (non-condensing) |
Port surge protection | All electrical ports: common mode 4 kV, differential mode 1 kV |
Packet forwarding rate | 17,800 Mpps |
---|---|
Line card slot | 10 |
Expansion slot | CM slots: 2 Line card slots: 10 Switch fabric module slots: 4 |
Fan module | 2 x M12-FAN-R fan modules |
Flash memory and SDRAM | Flash memory: ● ED/DC/EH card: 512 MB SDRAM: ● M18012-CM II: 16 GB ● M18012-FE-D I: DDRIII 1 GB ● ED/DC: 1 GB ● EF card: 2 GB ● 12CQ-EH/16XS2QXS: 4 GB |
Weight (empty chassis and fan modules) | 105 kg (231.49 lbs) |
Stacking bandwidth | ≥ 2.56 Tbps |
ACL entries | ● Maximum number of ingress ACEs associated with an SVI, physical interface, or aggregate interface ED card: 7,000 DC card: 8,000 EH card: 1,000 ● Maximum number of egress ACEs associated with an SVI, physical interface, or aggregate interface: 1,000 |
Number of IGMP groups | 1,024 |
Number of IPv6 unicast routes | IPv6 hardware routing table size: 6,000 (default) Size of the routing table with a subnet mask of 65 to 128 bits: 1,000 (default) |
Number of IPv4 unicast routes | 12,000 (default) |
ARP table size | ● ED card: 170,000 (default) ● DC card: 75,000 (default) ● EH card: 170,000 (default) |
System switching capacity | 24 Tbps |
Primary airflow | Front-to-rear airflow Supervisor module and line card: air inlet at the front bottom and air outlet at the top back (M12-FAN-R) |
Maximum input voltage | RG-PA1600I: 90 V to 264 V, 47 Hz to 63 Hz RG-PA600I: 90 V to 264 V, 47 Hz to 63 Hz RG-PD600I: –40 V DC to –75 V DC |
Maximum Power Consumption | RG-PA1600I: 90 V to 180 V Power: 1,200 W; 180 V to 264 V Power: 1,600 W RG-PA600I: 90 V to 180 V Power: 600 W; 180 V to 264 V Power: 600 W RG-PD600I: –40 V to –75 V Power: 600 W 210 V to 264 V Power: 3,000 W |
Storage humidity | 5% to 95% RH (non-condensing) |
Storage Temperature | –40°C to +70°C (–40°F to +158°F) |
Products