RG-N18012 Cloud Network Layer 3 Modular Core Switch with 12 Module Slots

    Key Specification
    NSE 3000
    Switch fabric module slot 4
    Supervisor module slot 2
    Power module System power: 6 PoE power: 2 (the power module must adapt to the PoE power frame)
    Data packet buffer ED card: 5 MB DC card: 16 MB 12CQ-EH: 16 MB
    CPU Supervisor module: ● M18012-CM II: 1.0 GHz 32-core processor Line card: ● ED/DC: 1.0 GHz quad-core processor Switch fabric module: ● M18012-FE-D I: 1.0 GHz quad-core processor
    Dimensions (W x D x H) 442 mm x 725 mm x 708.4 mm (17.40 in. x 28.54 in. x 27.89 in.), 16 RU
    Number of VSU members 2
    Number of MLD groups 1,024
    Number of IPv6 multicast routes ● ED card: 8,000 (default) ● DC card: 8,000 (default) ● EH card: 2,000 (default) and 4,000 (max.)
    Number of IPv4 multicast routes ● ED card: 16,000 (default) ● DC card: 16,000 (default) ● EH card: 4,000 (default) and 8,000 (max.)
    ND table size ED card: 75,000 (default) DC/EH card: 45,000 (default)
    MAC address Number of global MAC addresses: ● ED card: 128K (default) and 512K (max.) ● DC card: 96K (default) and 288K (max.) ● EH card: 136K (default) and 136K (max.) Number of static MAC addresses: 10,000
    Operating Temperature 0°C to 50°C (32°F to 122°F) with the height in the range of –500 m to +5,000 m (–1640.42 ft. to + 16404.20 ft.)
    MTBF > 200,000 hours
    Rated input voltage RG-PA1600I: 100 V to 120 V, 200 V to 240 V, 50/60 Hz RG-PA600I: 100 V to 120 V, 200 V to 240 V, 50/60 Hz RG-PD600I: –48 V DC
    Operating noise 63.5 dB at the temperature of 35°C (95°F) 77.4 dB at the temperature of 50°C (122°F)
    Operating Humidity 10% to 90% RH (non-condensing)
    Port surge protection All electrical ports: common mode 4 kV, differential mode 1 kV
    Packet forwarding rate 17,800 Mpps
    Line card slot 10
    Expansion slot CM slots: 2 Line card slots: 10 Switch fabric module slots: 4
    Fan module 2 x M12-FAN-R fan modules
    Flash memory and SDRAM Flash memory: ● ED/DC/EH card: 512 MB SDRAM: ● M18012-CM II: 16 GB ● M18012-FE-D I: DDRIII 1 GB ● ED/DC: 1 GB ● EF card: 2 GB ● 12CQ-EH/16XS2QXS: 4 GB
    Weight (empty chassis and fan modules) 105 kg (231.49 lbs)
    Stacking bandwidth ≥ 2.56 Tbps
    ACL entries ● Maximum number of ingress ACEs associated with an SVI, physical interface, or aggregate interface ED card: 7,000 DC card: 8,000 EH card: 1,000 ● Maximum number of egress ACEs associated with an SVI, physical interface, or aggregate interface: 1,000
    Number of IGMP groups 1,024
    Number of IPv6 unicast routes IPv6 hardware routing table size: 6,000 (default) Size of the routing table with a subnet mask of 65 to 128 bits: 1,000 (default)
    Number of IPv4 unicast routes 12,000 (default)
    ARP table size ● ED card: 170,000 (default) ● DC card: 75,000 (default) ● EH card: 170,000 (default)
    System switching capacity 24 Tbps
    Primary airflow Front-to-rear airflow Supervisor module and line card: air inlet at the front bottom and air outlet at the top back (M12-FAN-R)
    Maximum input voltage RG-PA1600I: 90 V to 264 V, 47 Hz to 63 Hz RG-PA600I: 90 V to 264 V, 47 Hz to 63 Hz RG-PD600I: –40 V DC to –75 V DC
    Maximum Power Consumption RG-PA1600I: 90 V to 180 V Power: 1,200 W; 180 V to 264 V Power: 1,600 W RG-PA600I: 90 V to 180 V Power: 600 W; 180 V to 264 V Power: 600 W RG-PD600I: –40 V to –75 V Power: 600 W 210 V to 264 V Power: 3,000 W
    Storage humidity 5% to 95% RH (non-condensing)
    Storage Temperature –40°C to +70°C (–40°F to +158°F)